Email Us

10G SFP+ SR Fiber Optic Transceiver

Identifier: 110060

Duplex LC | Multimode | ≤1W

Features

  • Duplex SFP+ Transceiver

  • Hot Pluggable

  • LC connector receptacle

  • Optical interface compliant to IEEE 802.3ae

  • Electrical interface compliant to SFF-8431

  • 2-wire interface with integrated Digital Diagnostic monitoring

  • Data rate up to 11.3Gbps

  • 850nm VCSEL transmitter, PIN photo-detector

  • Maximum link length of 300m on OM3 MMF

  • Power Dissipation < 1.0W

  • Case operation temperature range:

    Standard: temperature 0°C to 70°C

    Industrial temperature: -40°C to 85°C

  • RoHS6 compliant (lead free)

+ View More

Product Description of 10G SFP+ SR Fiber Optic Transceiver

The TSSLS-NAACB1 is a Single-Channel, Pluggable, Fiber-Optic SFP+ for 10.3125Gbps SR Applications. It is a high performance module for short-range data communication and interconnect applications which operate at 10.3125Gbps up to 82m on OM2 MMF and 300m on OM3 MMF.

This module is designed to operate over multimode fiber systems using a nominal wavelength of 850nm. The electrical interface uses a 20 contact edge type connector. The optical interface uses LC receptacle.

Specifications

Part NumberTSSLS-NAACB1Application10G Ethernet
Form FactorSFP+Max Data Rate11.3Gbps
Wavelength850nmDistance300m
ConnectorLCFiberMMF
TransmitterVCSELReceiverPIN
TX Power-6~-1dBmMinimum Receiver Power-11.1dBm
Power Budget5.1dBReceiver Overload-1dBm
Power Comsumption≤1WExtinction Ratio>3dB
PackagingCOBModulationNRZ
CDRNoInbuilt FECNo
Storage Temperature-40℃ ~ + 85℃Operating Temperature-40℃ ~ + 85℃
CompatibilityGenericClassIndustrial
ProtocolsIEEE 802.3ae,  SFF-8431Warranty


Absolute Maximum Ratings

These values represent the damage threshold of the module.  Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to the module even if all other parameters are within Recommended Operating Conditions.


Parameters

Symbol

Min.

Max.

Unit

Power Supply Voltage

VCC

-0.5

+3.6

V

Storage Temperature

Tc

-40

+85

°C

Relative Humidity

RH

0

85

%


Recommended Operating Conditions

Recommended Operating Environment specifies parameters for which the electrical and optical characteristics hold unless otherwise noted.


Parameter

Symbol

Min

Typical

Max

Unit

Power Supply Voltage

VCC

3.15

3.30

3.45

V

Operating Case Temperature (Standard)

Tca

0

-

70

°C

Operating Case Temperature (Industrial)

Tca

-40

-

85

°C

Notes:

[1] Supply current is shared between VCCTX and VCCRX.

[2] In-rush is defined as current level above steady state current requirements.

Electrical Characteristics

Parameter

Symbol

Min.

Typical

Max

Unit

Transmitter

Data Rate

Mra

1.0

10.3

11.3

Gbps

Input differential impedance1

Rin

-

100

-

Ω

Differential Input Voltage swing

Vin

150

-

1200

mV

Transmit Disable Voltage

VD

2.0

-

VCC+0.3

V

Transmit Enable Voltage2

Ven

Vee

-

Vee+0.8

V

Transmit Disable Assert Time

Vn

-

-

100

us

Receiver

Data Rate

Mra

-

10.3

11.3

Gbps

Output differential impedance1

Rout

-

100

-

Ω

Differential Output Swing3

Vout

300

-

700

mV

Loss of Signal –Asserted4

-

2.0

-

VCC+0.3

V

Loss of Signal –Negated4

-

Vee

-

Vee+0.8

V

Notes:

[1] AC coupled.

[2] Or open circuit.

[3] Into 100 ohm, differential termination.

[4] LOS is LVTTL. Logic 0 indicates normal operation; logic 1 indicates no signal detected.


Optical characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Transmitter

Center Wavelength

λ

840

850

860

nm

Average Optical Power1

Po

-6.0

-

-1

dBm

Extinction Ratio2

ER

3.5

-

-

dB

Transmitter Dispersion Penalty

TDP

-

-

3.9

dB

Optical Return Loss Tolerance

ORL

-

-

12

dB

Receiver

Receiver Sensitivity in OMA3

Rsens

-

-

-11.1

dBm

Stressed Sensitivity in OMA3

-

-

-

-7.5

dBm

Los function

Los

-30

-

-12

dBm

Receiver Overload3

Pmax

-1.0

-

-

dBm

Receiver Reflectance

-

-

-

-12

dB

Notes:

[1] The optical power is launched into MMF

[2] Measured with a PRBS 231-1 test pattern @10.3125Gbps

[3] Measured with a PRBS 231-1 test pattern @10.3125Gbps,BER≤10-12.

Low Speed Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

TX_Fault, RX_LOS

VOL

0

-

0.4

V

VOH

Host_VCC-0.5

-

Host_VCC+0.3

V

TX_DIS

VIL

-0.3

-

0.8

V

VIH

2.0

-

VCCT+0.3

V

RS0, RS1

VIL

-0.3

-

0.8

V

VIH

2.0

-

VCCT+0.3

V


SFP+ Transceiver Electrical Pad Layout

SFP+ Transceiver Electrical Pad Layout


Pin definition

Pin

Symbol

Name/Description

1

VEET [1]

Transmitter Ground

2

Tx_FAULT [2]

Transmitter Fault

3

Tx_DIS [3]

Transmitter Disable. Laser output disabled on high or open

4

SDA [2]

2-wire Serial Interface Data Line

5

SCL [2]

2-wire Serial Interface Clock Line

6

MOD_ABS [4]

Module Absent. Grounded within the module

7

RS0 [5]

Rate Select 0

8

RX_LOS [2]

Loss of Signal indication. Logic 0 indicates normal operation

9

RS1 [5]

Rate Select 1

10

VEER [1]

Receiver Ground

11

VEER [1]

Receiver Ground

12

RD-

Receiver Inverted DATA out. AC Coupled

13

RD+

Receiver DATA out. AC Coupled

14

VEER [1]

Receiver Ground

15

VCCR

Receiver Power Supply

16

VCCT

Transmitter Power Supply

17

VEET [1]

Transmitter Ground

18

TD+

Transmitter DATA in. AC Coupled

19

TD-

Transmitter Inverted DATA in. AC Coupled

20

VEET [1]

Transmitter Ground

Notes:

[1] Module circuit ground is isolated from module chassis ground within the module.

[2] Should be pulled up with 4.7k – 10k ohms on host board to a voltage between 3.15Vand 3.6V.

[3] Tx_Disable is an input contact with a 4.7 kΩ to 10 kΩ pullup to VCCT inside the module.

[4] Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull this contact up to VCC_Host with a resistor in the range 4.7 kΩ to10 kΩ.Mod_ABS is asserted “High” when the SFP+ module is physically absent from a host slot.

[5] RS0 and RS1 are module inputs and are pulled low to VeeT with > 30 kΩ resistors in the module.


Mechanical

multi mode 10g sfp sr optical transceiver mechanical


Ordering Information

Part Number

Product Description

TSSLS-NAACB1C

10G SFP+ SR Optical Transceiver 82m on OM2 MMF and 300m on OM3 MMF 0ºC ~ +70ºC

TSSLS-NAACB1T

10G SFP+ SR Optical Transceiver 82m on OM2 MMF and 300m on OM3 MMF -40ºC ~ +85ºC


Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by T&S before they become applicable to any particular order or contract. In accordance with the T&S policy of continuous improvement specifications may change without notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of T&S or others. Further details are available from any T&S sales representative.

Applications

  • 10GBASE-SR at 10.3125Gbps

  • 10GBASE-SW at 9.953Gbps

Compliance

RoHS, UL, CE, TUV, ISO14001, ISO45001, ISO9001

Need Help? Contact Our Product Experts or Sales Team Today!
  I agree with T&S’ Privacy Policy and Terms of Use
Recently Viewed
Get in Touch
Please be as detailed as possible have to help us understand your enquiry and help us find the right person to handle your request.
Factory Tour
Click to have a 720 degree factory tour of T&S factories.
Make an Appointment
Make an appointment for an on-site factory tour or an online consultation with our product experts.
Not exactly what you're looking for? Try our customized service!
T&S Communications Co., Ltd.
Latest News & Blog
Anti-Reflection (AR) and High-Reflection (HR) Optical Coatings
Oct 11, 2025
Anti-Reflection (AR) and High-Reflection (HR) Optical Coatings
Optical thin-film coatings play a critical role in controlling how light interacts with optical components. Among the most widely used are anti-reflection (AR) coatings, which minimize surface reflections and enhance transmission, and high-reflection (HR) coatings...
Co-Packaged Optics Powering the Next Era of Data Center Networking
Sep 30, 2025
Co-Packaged Optics Powering the Next Era of Data Center Networking
Co-Packaged Optics: Powering the Next Era of Data Center Networking The explosive growth of artificial intelligence (AI), high-performance computing (HPC), and next-generation networking models is res...
Game-Changer CPO: Paving the Way for Next-Generation High-Speed Networks
Sep 30, 2025
Game-Changer CPO: Paving the Way for Next-Generation High-Speed Networks
​The digital era is entering a new phase where Artificial Intelligence (AI), High-Performance Computing (HPC), Machine Learning (ML) and hyper-scale cloud platforms are demanding data speeds once thought impossible. Training a large language model, running real-time analytics...